Inductive integrated moving coil design is sturdy and durable to ensure long-term and high-reliability operation;
The upper limit frequency is as high as 7200Hz at full thrust force;
The operating frequency of shock response spectrum reaches 10kHz;
Different sizes of slip table and head expander can be flexibly configured in accordance with user requirement;
Three basic configurations: LP, CH and ST;
Easy integration with environmental chambers for combined testing and interlock control.
Model | DPU603HF-T183 |
Rated sine force (kN) | 18 |
Random force (kN) | 18 |
Shock force (kN) | 45 |
Shock load: 6ms, half-sine | 180g: no load |
Frequency range (Hz) | 5-7200 |
Max. acceleration (g) pk, sine | 150 |
Max. acceleration (g) rms, random | 100 |
Max. velocity (m/s) pk, sine | 1.8 |
Max. velocity (m/s) pk, shock | 5.5 |
Max. displacement p-p (mm) | 20*2 |
Max. load (kg) | 200 |
Mass of moving elements (kg) | 12.5 |
Armature diameter (mm) | 200 |
First-order resonance frequency (Hz) | 6200 ± 5 % |
Load connection points | 20 |
Screw size | M10 |
Body suspension nature frequency (Hz) | 3 |
@ Stray magnetic field (mT) | < 1 |
Dimension (L*W*H) (mm) | 800*1100*860 |
Weight (kg) | 1800 |
Power amplifier output power (kVA) | 60 |
Power amplifier weight (kg) | 540 |
Input impedance (kΩ) | > 10 |
Noise (dBA) | < 70 |
Power amplifier efficiency | > 90 % |
System protection | Over-voltage, over-current, over-temperature, etc. |
Power amplifier dimension (L*W*H) (mm) | 600*800*1300 |
Cooling type | air-cooled |
Model | BL153 |
Power (KVA) | 15 |
Weight (kg) | 240 |
System working environment requirements | |
Temperature (℃) | 0-40 |
Humidity (%) | 0-90 |
Power requirement (kVA) | 56 |
Compressed air requirement (Mpa) | 0.6 |
Notes:
1) The parameters listed represent maximum performance; for long-term operation, it is recommended to use at 70% capacity or below.
2) Maximum shock displacement is 25.4 mm peak-peak.
3) Unless otherwise specified, random force standards are based on 1505344 and JJG948-2018.
4) Specifications are subject to change without prior notice.