Vibration System

Vibration test system T183 series

Application

Features

  • Inductive integrated moving coil design is sturdy and durable to ensure long-term and high-reliability operation;

  • The upper limit frequency is as high as 7200Hz at full thrust force;

  • The operating frequency of shock response spectrum reaches 10kHz;

  • Different sizes of slip table and head expander can be flexibly configured in accordance with user requirement;

  • Three basic configurations: LP, CH and ST;

  • Easy integration with environmental chambers for combined testing and interlock control.


Technical Parameter

Model

DPU603HF-T183

Rated sine force (kN)

18

Random force (kN)

18

Shock force (kN)

45

Shock load: 6ms, half-sine

180g: no load

Frequency range (Hz)

5-7200

Max. acceleration (g) pk, sine

150

Max. acceleration (g) 

rms, random

100

Max. velocity (m/s) pk, sine

1.8

Max. velocity (m/s) pk, shock

5.5

Max. displacement p-p (mm)

20*2

Max. load (kg)

200

Mass of moving elements (kg)

12.5

Armature diameter (mm)

200

First-order resonance 

frequency (Hz)

6200 ± 5 %

Load connection points

20

Screw size

M10

Body suspension nature 

frequency (Hz)

3

@ Stray magnetic field (mT)

< 1

Dimension (L*W*H) (mm)

800*1100*860

Weight (kg)

1800

Power amplifier output 

power (kVA)

60

Power amplifier weight (kg)

540

Input impedance (kΩ)

> 10

Noise (dBA)

< 70

Power amplifier efficiency

> 90 %

System protection

Over-voltage, over-current,   over-temperature, etc.

Power amplifier dimension 

(L*W*H) (mm)

600*800*1300

Cooling type

air-cooled

Model

BL153

Power (KVA)

15

Weight (kg)

240

System working 

environment requirements


Temperature (℃)

0-40

Humidity (%)

0-90

Power requirement (kVA)

56

Compressed air 

requirement (Mpa)

0.6

Notes:

1) The parameters listed represent maximum performance; for long-term operation, it is recommended to use at 70% capacity or below.

2) Maximum shock displacement is 25.4 mm peak-peak.

3) Unless otherwise specified, random force standards are based on 1505344 and JJG948-2018.