Vibration System

Vibration test system R103 series

Application

S103 series offers advantages such as a wide frequency range, light weight, easy maintenance. It is widely used in aerospace & aviation, industrial electronics, automotive parts, rail transport, new energy, communications and other fields. It is mainly used to simulate the vibration environments encountered by products during manufacturing, transportation and use. Typical test applications include the development and screening of electronic products.


Features

  • A higher load-bearing meets the system long-term operation;

  • Standard automatic centering configuration combines both high performance and high reliability;

  • Configuration of ST (Slip table) can be provided with different table sizes and guide rails according to user needs;

  • After factory commissioning and calibration of the slip table is completed, only a horizontal flip adjustment can achieve long term and easy docking.

Technical Parameter

Model

DPS123-R103

DPS123-R103LS3

Rated sine force (kN)

10

10

Random force (kN)

10

10

Shock foce (kN)

20

20

Frequency range (Hz)

DC-3500

DC-3000

Max. acceleration (g)

pk, sine

100

85

Max. acceleration (g)

rms, random

100

85

Max. velocity (m/s)

pk, sine

1.8

1.8

Max. velocity (m/s)

pk, shock

3.4

3.4

Max. displacement

p-p(mm)

51

76

Max. load (kg)

400

400

Mass of moving

elements (kg)

10

12

Armature diameter (mm)

240

240

First-order resonance 

frequency (Hz)

2650

2300

Load connection points

13

 Screw size

M10

Body suspension nature frequency (Hz)

3

@ Stray magnetic field (mT)

<1 mT

Dimension (L*W*H)(mm)

720*750*750

Weight (kg)(approximately)

900

Power amplifier output 

power (kVA)

12

Power amplifier weight (kg)

270

Input impedance (kΩ)

>10

Signal-to-noise ratio (dB)

>70

Power amplifier efficiency

>90%

System protection

Over-voltage, over-current, over-temperature, etc.

Power amplifier dimension 

(L*W*H)(mm)

600*800*1300

Cooling type

air-cooled

Model

B402

Power (KVA)

4

Weight (kg)

120

System working environment

requirements


Temperature (℃)

0-40

Humidity (%)

0-90

Power requirement (kVA)

21

Compressed air 

requirement (Mpa)

0.6

Notes:

1) Unless otherwise specified, random force standards are based on 1505344 and JJG948-2018.

2) Specifications are subject to change without prior notice.