S103 series offers advantages such as a wide frequency range, light weight, easy maintenance. It is widely used in aerospace & aviation, industrial electronics, automotive parts, rail transport, new energy, communications and other fields. It is mainly used to simulate the vibration environments encountered by products during manufacturing, transportation and use. Typical test applications include the development and screening of electronic products.
A higher load-bearing meets the system long-term operation;
Standard automatic centering configuration combines both high performance and high reliability;
Configuration of ST (Slip table) can be provided with different table sizes and guide rails according to user needs;
After factory commissioning and calibration of the slip table is completed, only a horizontal flip adjustment can achieve long term and easy docking.
Model | DPS123-R103 | DPS123-R103LS3 |
Rated sine force (kN) | 10 | 10 |
Random force (kN) | 10 | 10 |
Shock foce (kN) | 20 | 20 |
Frequency range (Hz) | DC-3500 | DC-3000 |
Max. acceleration (g) pk, sine | 100 | 85 |
Max. acceleration (g) rms, random | 100 | 85 |
Max. velocity (m/s) pk, sine | 1.8 | 1.8 |
Max. velocity (m/s) pk, shock | 3.4 | 3.4 |
Max. displacement p-p(mm) | 51 | 76 |
Max. load (kg) | 400 | 400 |
Mass of moving elements (kg) | 10 | 12 |
Armature diameter (mm) | 240 | 240 |
First-order resonance frequency (Hz) | 2650 | 2300 |
Load connection points | 13 | |
Screw size | M10 | |
Body suspension nature frequency (Hz) | 3 | |
@ Stray magnetic field (mT) | <1 mT | |
Dimension (L*W*H)(mm) | 720*750*750 | |
Weight (kg)(approximately) | 900 | |
Power amplifier output power (kVA) | 12 | |
Power amplifier weight (kg) | 270 | |
Input impedance (kΩ) | >10 | |
Signal-to-noise ratio (dB) | >70 | |
Power amplifier efficiency | >90% | |
System protection | Over-voltage, over-current, over-temperature, etc. | |
Power amplifier dimension (L*W*H)(mm) | 600*800*1300 | |
Cooling type | air-cooled | |
Model | B402 | |
Power (KVA) | 4 | |
Weight (kg) | 120 | |
System working environment requirements | ||
Temperature (℃) | 0-40 | |
Humidity (%) | 0-90 | |
Power requirement (kVA) | 21 | |
Compressed air requirement (Mpa) | 0.6 | |
Notes:
1) Unless otherwise specified, random force standards are based on 1505344 and JJG948-2018.
2) Specifications are subject to change without prior notice.