Vibration System

Vibration test system R403 series

Application

Features

  • The operation frequency in a high frequency configuration can be up to 5000Hz;

  • A higher sine, random and shock capabilities, with higher load-bearing, to meet system long-term operation;

  • It can achieve a shock testing with acceleration up to 200g;

  • Standard automatic centering configuration combines both high performance and high reliability;

  • Different sizes of slip table and head expander can be flexibly configured in accordance with user requirement;

  • Three basic configurations: LP, CH and ST;

  • Easy integration with environmental chambers for combined testing and interlock control.


Technical Parameter


Model

DPU303-R403-340

DPU603-R403-340

DPU603-R403HF-340

Rated sine force (kN)

36

40

30

Random force (kN)

36

40

30

Shock/load: 4ms, half-sine

50 g:110 kg/100 g:45 kg

50 g:125 kg/100 g:50 kg

50 g:125 kg/100 g:50 kg

Shock/load: 11ms, half-sine

30 g:200 kg/50 g:90 kg

30 g:120 kg/50 g:125 kg

30 g:120 kg/50 g:110 kg

Frequency range (Hz)

DC-3000

DC-3000

DC-5000

Max. acceleration (g) pk, sine

130

150

123

Max. acceleration (g) 

rms, random

100

120

100

Max. velocity (m/s)pk, sine

1.4

19

19

Max. velocity (m/s)pk, shock

2

3.5

3.5

Max. displacement p-p(mm)

51

Max. load (kg)

600

Mass of moving elements (kg)2729.5

Armature diameter (mm)

340

First-order   

resonance frequency (Hz)

23502800

Load connection points

21

Table screw size

M12

Body suspension nature 

frequency (Hz)

3

@ Stray magnetic field (mT)

<1 mT

Dimension (L*W*H)(mm)

1200*1000*920

Weight (kg)

2500

Power amplifier output 

power (kVA)

30

60

60

Power amplifier weight (kg)

550

Input impedance (kΩ)

10

Signal-to-noise ratio (dB)

>70

Power amplifier efficiency

>90%

System protection

Over-voltage, over-current, over-temperature, etc.

Power amplifier dimension 

(L*W*H)(mm)

600*800*1900

Cooling type

air-cooled

Model

B153

B223

B233

Power (KVA)

11.5

22

22

Weight (kg)

240

300

300

System working 

environment requirements


Temperature (℃)

0-40

Humidity (%)

0-90

Power

requirement (kVA)

60

70

70

Compressed air requirement

(Mpa)

0.6


Remarks:

1) The index parameters are the maximum performance, and it is recommended to use less than 70% for long-term use.

2) According to user needs, different sizes of horizontal and extended countertops can be flexibly configured.

3) Unless otherwise specified, the random thrust standard is based on 1505344 and JJG948-2018. 

4) Specifications are subject to change without notice.