文章
  • 文章
  • 产品
Search

English


HOME >> Products Center >>Shock/ bump system >> KCT11 series pneumatic vertical shock/ bump test system
Product Detail

KCT11 series pneumatic vertical shock/ bump test system

Collect
Description:

KCT11 series is a full pneumatic vertical shock/ bump test system. It is a shock /bump test equipment with novel design, 

high degree of automation, good safety and reliability, simple operation and convenient maintenance. The system can 

perform the shock test of general half sine wave, post peak sawtooth wave, square wave and other waveforms. It can 

meet the requirements of shock test and meet the requirements of bump test. The system equipped with the shock bump

 control measuring instrument, effectively integrates the shock and bump functions, and the function is perfect and reliable.

 

Functions and features:

 Use fully air pressure drive, with simple structure, high reliability. And no pollution, can keep the environment clean and

 tidy.

 It is no need to do shock and bump conversion, measurement and control software can automatically complete shock 

or bump test.

 Using air pressure drive, the shock test efficiency is greatly improved, and the maximum shock rate can be up to 100 

times/min.

 Convenient to achieve large pulse width and small overload test.

 It can be used to replace a bump tester due to its shock tester structure and high shock rate. Compared with motor 

drive or hydraulic drive bump tester, it has higher reliability and better bump waveform.

 It can control the shock speed by adjusting the air pressure, and easy to adjust the bump speed.

Control measurement software uses KCT90 series shock control and measurement software, which can conduct shock

 manual operation, continuous shock, single shock , interval shock, and realize various kinds of shock modes, which is 

convenient for users to choose.

 Built-in brake mechanism, using air pressure to unlock, and tightly locked when electromagnetic valve is power off, to 

ensure safe operation under any circumstances.Ø

 

Technical parameter:

Model 

KCT11-25

KCT11-50

Rated load (kg)

25

50

Table size (mm)

350*300 mm 

500*500 mm

Shock waveform

Half sine

Post peak sawtooth

Half sine

Post peak sawtooth

Trapezoid

Shock peak acceleration (m/s2)

100~

8500

100~2000

100~

7000

100~2000

150~1000

Shock pulse duration (ms)

40~0.8

18~3

40~1

18~3

12~6

Bump waveform

Half sine wave

Bump peak acceleration (m/s2)

50~1500

50~1000

Bump pulse duration (ms)

30~3

30~3

Overall dimensions (mm)

900*800*2000

1300*1000*2100

Weight (kg)

1000

1800

Max. frequency times (times/min)

100

80

Power supply requirements for Table

AC 220V±10%, 50Hz, 2kVA

Power supply requirements for Air 

compressor

AC 220V±10%, 50Hz, 3kVA or 

AC 380V±10%, three-phase, 50Hz, 5kVA 

Air source conditions

Air source output pressure is not more than 1.0Mpa. 

If there is no air source in the lab, air compressor needs to be 

configured; 

If there is air source in the lab, and there is a high requirement on the 

bump frequency times, it needs to configure a corresponding air storage 

tank.

Environment temperature

0~40℃

Humidity (%)

≤90% (25℃), non condense



Model 

KCT11-100

KCT11-200

Rated load (kg)

100

200

Table size (mm)

800*600 mm 

800*800 mm

Shock waveform

Half sine

Post peak sawtooth

Trapezoid

Half sine

Post peak sawtooth

Trapezoid

Shock peak acceleration 

(m/s2)

100~

3000

100~

1000

150~

1000

100~2000

100~600

150~600

Shock pulse duration (ms)

40~

1.5

18~3

12~6

40~2

18~6

12~6

Bump waveform

Half sine wave

Bump peak acceleration 

(m/s2)

50~1000

50~1000

Bump pulse duration (ms)

30~3

30~3

Overall dimensions (mm)

1500*1300*2350

1550*1440*2400

Weight (kg)

2500

2800

Max. frequency times 

(times/min)

80

60

Power supply 

requirements for Table

AC 220V±10%, 50Hz, 2kVA

Power supply 

requirements for Air 

compressor

AC 220V±10%, 50Hz, 3kVA or 

AC 380V±10%, three-phase, 50Hz, 5kVA 

Air source conditions

Air source output pressure is not more than 1.0Mpa. 

If there is no air source in the lab, air compressor needs to be configured; 

If there is air source in the lab, and there is a high requirement on the 

bump frequency times, it needs to configure a corresponding air storage tank.

Environment temperature

0~40℃

Humidity (%)

≤90% (25℃), non condense

Model 

KCT11-400

KCT11-600

Rated load (kg)

400

600

Table size (mm)

1000*800 mm 

1000*1000 mm

Shock waveform

Half sine

Post peak sawtooth

Trapezoid

Half sine

Post peak sawtooth

Trapezoid

Shock peak acceleration 

(m/s2)

100~

2000

100~600

150~600

100~2000

100~600

150~600

Shock pulse duration (ms)

40~3

18~6

12~6

40~3

18~6

12~6

Bump waveform

Half sine wave

Bump peak acceleration 

(m/s2)

50~1000

50~1000

Bump pulse duration (ms)

30~3

30~3

Overall dimensions (mm)

1600*1450*2450

1750*1600*2500

Weight (kg)

3800

4000

Max. frequency times 

(times/min)

50

40

Power supply requirements 

for Table

AC 220V±10%, 50Hz, 2kVA

Power supply requirements 

for Air compressor

AC 220V±10%, 50Hz, 3kVA or 

AC 380V±10%, three-phase, 50Hz, 5kVA 

Air source conditions

Air source output pressure is not more than 1.0Mpa. 

If there is no air source in the lab, air compressor needs to be configured; 

If there is air source in the lab, and there is a high requirement on the bump

 frequency times, it needs to configure a corresponding air storage tank.

Environment temperature

0~40℃

Humidity (%)

≤90% (25℃), non condense

Model 

KCT11-800

KCT11-1000

Rated load (kg)

800

1000

Table size (mm)

1200*1000 mm 

1200*1200 mm

Shock waveform

Half sine

Post peak sawtooth

Trapezoid

Half sine

Post peak sawtooth

Trapezoid

Shock peak acceleration 

(m/s2)

100~1000

100~500

150~500

100~1000

100~500

150~500

Shock pulse duration (ms)

40~4

18~6

12~6

40~4

18~6

12~6

Bump waveform

Half sine wave

Bump peak acceleration 

(m/s2)

50~800

50~600

Bump pulse duration (ms)

30~3

30~3

Overall dimensions (mm)

1950*1750*2600

2100*1900*2700

Weight (kg)

4800

5200

Max. frequency times 

(times/min)

30

30

Power supply requirements 

for Table

AC 220V±10%, 50Hz, 2kVA

Power supply requirements

 for Air compressor

AC 220V±10%, 50Hz, 3kVA or 

AC 380V±10%, three-phase, 50Hz, 5kVA 

Air source conditions

Air source output pressure is not more than 1.0Mpa. 

If there is no air source in the lab, air compressor needs to be configured; 

If there is air source in the lab, and there is a high requirement on the bump 

frequency times, it needs to configure a corresponding air storage tank.

Environment temperature

0~40℃

Humidity (%)

≤90% (25℃), non condense

Model 

KCT11-2000

Rated load (kg)

2000

Table size (mm)

1500*1200 mm 

Shock waveform

Half sine

 

Post peak sawtooth

Trapezoid

Shock peak acceleration (m/s2)

100~1000

100~500

150~500

Shock pulse duration (ms)

40~6

18~6

12~6

Bump waveform

Half sine wave

Bump peak acceleration (m/s2)

50~400

Bump pulse duration (ms)

30~3

Overall dimensions (mm)

2500*2200*2850

Weight (kg)

6000

Max. frequency times (times/min)

20

Power supply requirements for Table

AC 220V±10%, 50Hz, 2kVA

Power supply requirements for Air compressor

AC 220V±10%, 50Hz, 3kVA or 

AC 380V±10%, three-phase, 50Hz, 5kVA 

Air source conditions

Air source output pressure is not more than 1.0Mpa. 

If there is no air source in the lab, air 

compressor needs to be configured; 

If there is air source in the lab, and there

 is a high requirement on the bump

 frequency times, it needs to configure a

 corresponding air storage tank.

Environment temperature

0~40℃

Humidity (%)

≤90% (25℃), non condense

Notes: For the specifications of the large table, small pulse width and high acceleration, it only be fulfilled with the 

support of shock amplifier.

 

Main technical parameter of KCT90 series shock control and measuring instrument:

 KCT90-1: peak acceleration: 1~5000g; pulse duration: 0.1ms~100ms;

 KCT90-2: peak acceleration: 2000~100000g; pulse duration:0.01ms~10ms;

 It provides 2 to 4 channels of BNC signal input interface;

 It can connect various acceleration sensors and amplifiers.


+86-29-89182431, +86-29-89194421
friday@hydescience.com
710065, Room 1906, Block E, Van Metropolis, Road Tangyan, Xi'an, China
Mobile version
About Hyde
Products Center
News
Products Service
Technical Support: 艺源科技 | Admin Login
×